{"product_id":"getwell-osmo-slim-3000g-ipari-ro-rendszer-500-l-h","title":"GetWell OSMO SLIM 3000G industrial RO system – 500 l\/h","description":"\u003ch3\u003eGetWell OSMO SLIM 3000G – industrial reverse osmosis system, 500 l\/h\u003c\/h3\u003e\r\n\r\n\u003cp\u003eThe GetWell \u003cstrong\u003eOSMO SLIM 3000G\u003c\/strong\u003e industrial reverse osmosis (RO) unit produces \u003cstrong\u003e500 litres\u003c\/strong\u003e of purified water per hour, equivalent to \u003cstrong\u003eapprox. 12,000 litres\u003c\/strong\u003e of permeate per day in continuous operation. The unit works with 2 × 4040 RO membranes in FRP composite pressure vessels.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eWho is this series for?\u003c\/h3\u003e\r\n\r\n\u003cp\u003eA narrow frame for tight plant rooms or for installation alongside existing equipment. It makes sense where floor space, not output, is the bottleneck.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eWhat does reverse osmosis remove?\u003c\/h3\u003e\r\n\r\n\u003cp\u003eRO is the finest pressure-driven membrane filtration process: the semi-permeable membrane retains the vast majority of the water's dissolved salts, hardness, nitrate and heavy metals, as well as microbiological contaminants. The resulting low-conductivity water is needed wherever raw water quality alone is not sufficient for the process:\r\n\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eFood and beverage industry:\u003c\/strong\u003e recipe water, bottling, brewing, soft drink production – where the taste and salt content of the water go directly into the product\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eHoReCa:\u003c\/strong\u003e central kitchen and bar water supply, ice machines, coffee machines, combi ovens and steamers – here, scale protection translates directly into equipment service life\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003ePharmaceutical industry and laboratories:\u003c\/strong\u003e the first stage of purified water production, upstream of EDI or ion exchange\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eIndustrial processes:\u003c\/strong\u003e boiler and cooling circuit make-up water, surface treatment, rinse water\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eAgriculture:\u003c\/strong\u003e desalination of irrigation water, hydroponics, where high salt content limits crop yields\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003ch3\u003eConfiguration\u003c\/h3\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e2 × 4040 RO membranes in FRP composite pressure vessels\u003c\/li\u003e\r\n\t\u003cli\u003eHigh-pressure feed pump, 230 V mains supply\u003c\/li\u003e\r\n\t\u003cli\u003eIndustrial control panel with automatic flushing and status indication\u003c\/li\u003e\r\n\t\u003cli\u003eHigh- and low-pressure switches to protect the pump\u003c\/li\u003e\r\n\t\u003cli\u003eSolenoid valve for controlling feed and flushing\u003c\/li\u003e\r\n\t\u003cli\u003eFlow meters on the permeate and concentrate lines\u003c\/li\u003e\r\n\t\u003cli\u003ePressure gauges for monitoring pressure upstream and downstream of the membrane\u003c\/li\u003e\r\n\t\u003cli\u003eReady-to-install, enclosed frame\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eImportant note on output:\u003c\/strong\u003e the rated output applies to a feed water temperature of 25 °C and raw water quality as specified in the membrane data sheet. With colder water or higher salt content, the actual output will be lower – with 10 °C winter water, capacity can drop to as little as half the rated value. That is why we always ask for a water analysis for sizing.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003ePretreatment – the key to equipment service life\u003c\/h3\u003e\r\n\r\n\u003cp\u003eThe RO membrane is the most expensive wear part, and in practice it almost never fails through a fault of the membrane itself, but because of inadequate pretreatment. The following are always required upstream of the unit:\r\n\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eMechanical pre-filtration\u003c\/strong\u003e – typically in 20 and 5 micron stages, to retain suspended solids.\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eActivated carbon filtration\u003c\/strong\u003e – free chlorine irreversibly damages the polyamide membrane. This is the most common cause of premature membrane failure.\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eWater softening or antiscalant dosing\u003c\/strong\u003e – with hard water, calcium and magnesium salts precipitate on the membrane surface and permanently reduce output.\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eIron and manganese removal\u003c\/strong\u003e – almost always necessary with well water, as oxidising iron clogs the membrane.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003eCorrect pretreatment can only be designed on the basis of a laboratory analysis of the raw water. Send us your water analysis and we will size the \u003cstrong\u003ecomplete system\u003c\/strong\u003e – not just the RO unit.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eInstallation and operation\u003c\/h3\u003e\r\n\r\n\u003cp\u003eInstalling an industrial RO system is a job for specialists: it requires adequate feed pressure and water volume, concentrate drainage, an electrical connection and permeate storage. Bear in mind too that part of the feed water is discharged as concentrate – the proportion depends on raw water quality and the set recovery rate.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003eCommissioning and regular maintenance – membrane cleaning, pre-filter replacement, output and conductivity measurement – are best handled under a service contract. Regular performance measurement is the only way to detect membrane deterioration in time.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eFiltration performance\u003c\/h3\u003e\r\n\r\n\u003cp\u003eThe unit is fitted with a \u003cstrong\u003eWATERRO LP-4040-3000\u003c\/strong\u003e polyamide thin-film composite (TFC) industrial RO membrane. Its stable salt rejection according to the manufacturer's data sheet is \u003cstrong\u003e99.5%\u003c\/strong\u003e, under the following test conditions: 1,500 mg\/l NaCl solution, 10.3 bar (150 psi) operating pressure, 25 °C, pH 7.0 ±0.5, 15% recovery. Without the test conditions the percentage on its own is not a comparable figure, which is why we state them.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003eRejection varies by component. The ranges below are general empirical values typical of polyamide RO membranes, not the manufacturer's own measurements:\r\n\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003eDivalent ions (calcium, magnesium, sulphate): 98–99.5%\u003c\/li\u003e\r\n\t\u003cli\u003eMonovalent ions (sodium, chloride): 95–99%\u003c\/li\u003e\r\n\t\u003cli\u003eNitrate, fluoride: 90–95%\u003c\/li\u003e\r\n\t\u003cli\u003eHeavy metals (lead, cadmium, chromium): 95–98%\u003c\/li\u003e\r\n\t\u003cli\u003eBacteria, cysts, viruses, microplastics: more than 99.99%\u003c\/li\u003e\r\n\t\u003cli\u003eFree chlorine and dissolved gases (CO₂, O₂, H₂S): not retained by the membrane\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003e\u003cstrong\u003eOperating limits:\u003c\/strong\u003e max. 3,000 ppm feed TDS, max. 45 °C water temperature, max. SDI15 = 5, free chlorine below 0.1 ppm, pH 3–10. Compliance with these limits is also a condition of the warranty – especially the chlorine limit, as exceeding it irreversibly damages the membrane.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eRecommended pre-filtration – protecting the membrane\u003c\/h3\u003e\r\n\r\n\u003cp\u003eThis unit \u003cstrong\u003edoes not include a pre-filter\u003c\/strong\u003e. The RO membrane is the most expensive wear part of the system, and in practice it almost never fails on its own, but because of missing or undersized pretreatment. We therefore recommend pre-filtration for every installation – at three levels:\r\n\u003c\/p\u003e\r\n\r\n\u003cul\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003e3M™ Aqua-Pure™ AP055T\u003c\/strong\u003e – for retaining suspended solids and sediment. This is the minimum: it prevents particulate matter from depositing on the membrane surface and reducing output.\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003eAP055T + 3M™ Aqua-Pure™ AP117NP\u003c\/strong\u003e – the AP117NP is a 5-micron activated carbon depth filter cartridge in a 10\" format. It is important for removing free chlorine: chlorine irreversibly damages the polyamide membrane and is the most common cause of premature membrane failure. For systems running on chlorinated mains water, we consider this pair the standard set-up.\u003c\/li\u003e\r\n\t\u003cli\u003e\n\u003cstrong\u003e3M™ Aqua-Pure™ AP903\u003c\/strong\u003e – a complete high-flow pre-filter system in a single unit, with a hygienic quick-change cartridge. We recommend this for higher water demand and continuous multi-shift operation.\u003c\/li\u003e\r\n\u003c\/ul\u003e\r\n\r\n\u003cp\u003eWith hard water, water softening or antiscalant dosing is also required alongside pre-filtration, and with well water, iron and manganese removal as well. Exactly what is needed depends on the laboratory analysis of the raw water – send us your water analysis and we will size the complete line.\r\n\u003c\/p\u003e\r\n\r\n\u003ch3\u003eScale inhibition where no water softener is installed\u003c\/h3\u003e\r\n\r\n\u003cp\u003eWith hard water, mechanical and activated carbon pre-filtration alone is not enough: calcium and magnesium salts precipitate on the membrane surface and permanently reduce output. Where no water softener is installed, the \u003cstrong\u003e3M™ Aqua-Pure™ SF18-S\u003c\/strong\u003e scale inhibition cartridge can be considered as entry-level protection. Using sequestration technology, it keeps hardness salts in solution so they cannot deposit.\r\n\u003c\/p\u003e\r\n\r\n\u003cp\u003eIt is important to keep this in perspective: sequestration capacity is limited and decreases in proportion to water hardness and flow. For higher-capacity machines and persistently hard water, \u003cstrong\u003ewater softening or antiscalant dosing\u003c\/strong\u003e is the right solution – the SF18-S complements these, it does not replace them. Which one is needed depends on the hardness of the raw water and the planned recovery rate.\r\n\u003c\/p\u003e\n\u003ch3\u003eTechnical data\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated output\u003c\/td\u003e\n\u003ctd\u003e500 l\/h (3000 GPD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDaily capacity (24 h)\u003c\/td\u003e\n\u003ctd\u003eapprox. 12,000 litres\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane\u003c\/td\u003e\n\u003ctd\u003e2 × 4040 RO membranes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane housing material\u003c\/td\u003e\n\u003ctd\u003eFRP composite\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e230 V \/ 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDesign\u003c\/td\u003e\n\u003ctd\u003eSpace-saving, ready-to-install unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane type\u003c\/td\u003e\n\u003ctd\u003eWATERRO LP-4040-3000, polyamide thin-film composite (TFC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalt rejection\u003c\/td\u003e\n\u003ctd\u003e99.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eActive membrane area\u003c\/td\u003e\n\u003ctd\u003e9.3 m² (100 ft²) per element\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMembrane element size\u003c\/td\u003e\n\u003ctd\u003e1016 × 99.7 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. feed TDS\u003c\/td\u003e\n\u003ctd\u003e3,000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. feed temperature\u003c\/td\u003e\n\u003ctd\u003e45 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. free chlorine\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. SDI15\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range (operation)\u003c\/td\u003e\n\u003ctd\u003e3–10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH range (chemical cleaning)\u003c\/td\u003e\n\u003ctd\u003e2–12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. operating pressure\u003c\/td\u003e\n\u003ctd\u003e41.4 bar (600 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer part number\u003c\/td\u003e\n\u003ctd\u003e1000001060\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"GetWell","offers":[{"title":"Default Title","offer_id":55378458837331,"sku":"GW-SLIM-3000-FRP","price":1123950.0,"currency_code":"HUF","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1115\/3339\/2211\/files\/getwell-osmo-slim-RO-3000g_01.jpg?v=1792000145","url":"https:\/\/fastfilter.hu\/en\/products\/getwell-osmo-slim-3000g-industrial-ro-system-500-l-h","provider":"FastFilter","version":"1.0","type":"link"}